True Airspeeds
These true speed indicators are differential pressure indicators that measure the difference between static and total pressure produced by ram air from the pitot. The indicated airspeed can be corrected for changes in altitude by turning the knob to align the outside air temperature with the altitude. The moveable airspeed scale will then show the actual, or true, airspeed. |
|
- Options
- EA5174-PTL Specs
- EA5175-PTL Specs
- EA5176-PTL Specs
Physical Characteristics | |||||||||||||||||||||||||||||||
Dial 1
|
|||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||
Notes:
|
Dials Available
Dial 2 |
Dial 3 |
|
40 to 200 MPH |
35 to 170 Knots |
Environmental Characteristics
Temperature: | -30° to 50° C |
Vibration: | |
- CPS: | 5 to 50 |
- Maximum Double Amplitude: | 0.020 in. |
- Maximum Acceleration: | 1.5 G's |
Humidity: | 0% to 95% at 32° C |
Altitude: | 0 to 40,000 ft. |
Physical Characteristics | |||||||||||||||||||||||||||||||
Dial 1
|
|||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||
Notes:
|
Dials Available
Dial 2 |
Dial 3 |
40 to 240 MPH |
40 to 210 Knots |
Environmental Characteristics
Temperature: | -30° to 50° C |
Vibration: | |
- CPS: | 5 to 50 |
- Maximum Double Amplitude: | 0.020 in. |
- Maximum Acceleration: | 1.5 G's |
Humidity: | 0% to 95% at 32° C |
Altitude: | 0 to 40,000 ft. |
Physical Characteristics | |||||||||||||||||||||||||||||||
Dial 1
|
|||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||
Notes:
|
Dials Available
Dial 2 |
|
40 to 260 MPH |
Environmental Characteristics
Temperature: | -30° to 50° C |
Vibration: | |
- CPS: | 5 to 50 |
- Maximum Double Amplitude: | 0.020 in. |
- Maximum Acceleration: | 1.5 G's |
Humidity: | 0% to 95% at 32° C |
Altitude: | 0 to 40,000 ft. |