1U647-001 AC Calibration Standard
1U647-001 AC Calibration Standard

The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.

back
  • Specifications
Physical Characteristics
1U647-001 top view
Dimensions
Depth:
9.20 ± 0.10 in.
Width:
12.20 ± 0.10 in.
Height:
5.00 ± 0.10 in.
Weight:
6 lbs.
Connectors
Fuel Quantity: MS27508E10F35SN
Extender Card: D38999 / 20FF35PN
Power
Input Voltage: 28 VDC
Input Current: 80 mA
DC Output Settings
DC:
1, 10 VDC
PWM:
0, 95% D.C.
ARINC 429:
Lo:1,2,3 & High
AC Output Settings
Resolver:
0°,45°,90°,135°,
180°,225°,270°,315°
LVDT:
Extend: 14.31"
Retract: 18.71"
RVT: